Checks Before Eye-hand Calibration
About 870 wordsAbout 3 min
Complete the checks on this page before collecting eye-hand calibration samples. Loose mounting, imaging problems, or robot accuracy issues will directly affect the calibration results.
1. Check the Basic Configuration
Confirm that the following preparations are complete:
- Install and connect the robot, camera, and industrial PC according to the Hardware Installation Guide
- Create a project and task according to the Project Operation Guide and Task Operation Guide
- Connect the camera and adjust its imaging parameters according to the Camera Connection and Parameter Adjustment Guide
- Set up robot communication according to the Robot Configuration Guide
- Confirm that the robot type, pose field order, pose units, and current coordinate system match the onsite configuration
2. Check the Robot Installation
- The robot mounting surface should be level and clean
- The mounting bolts between the robot body and base should be tight
- Command the robot to make large translational or rotational movements at 100% speed. The robot body and base should show no noticeable shaking, displacement, or tilting
If the robot shakes, secure its base again before checking its accuracy and performing eye-hand calibration.
3. Check the Camera and Bracket
- The camera bracket should provide stable support. Avoid structures that are prone to shaking
- Check the bracket by hand to confirm that it does not noticeably shake or slip
- Check the connection between the camera and bracket, and confirm that the mounting points and bolts are tight
- The camera and bracket must not move during sampling
For an eye-in-hand setup, also confirm that the camera is securely connected to the robot end-effector. For an eye-to-hand setup, confirm that the external bracket remains stable while the robot moves.
4. Check Camera Imaging and the Point Cloud
- Confirm that the entire Calibration Board is visible within the camera’s field of view
- Check image exposure to avoid obvious overexposure or underexposure
- Check that the concentric circles on the Calibration Board can be detected consistently
- Check the Point Cloud for large missing areas, obvious noise, or distortion
- If camera accuracy is uncertain, follow the camera accuracy correction procedure in Common Issues and FAQ
If the images or Point Cloud do not meet the requirements, adjust the camera parameters before collecting calibration samples.
5. Check the Calibration Board and Needle-Tip Tool
The Calibration Board should be flat and clearly marked, with no obvious scratches, dirt, bends, or deformation. Check the mounting arrangement for the calibration method:
| Calibration setup | Calibration Board and tool arrangement |
|---|---|
| Eye-in-hand random-pose sampling | Place the Calibration Board securely on the work platform; the camera moves with the robot |
| Eye-to-hand random-pose sampling | Mount the Calibration Board securely on the robot end-effector; the camera remains fixed |
| Point probing with a needle-tip tool | Fix the Calibration Board on the work platform and mount the needle-tip tool on the robot end-effector |
For random-pose sampling, the Calibration Board should cover multiple areas of the camera’s field of view. For point probing with a needle-tip tool, confirm that the needle-tip tool coordinate system is set correctly.
6. Check Robot Accuracy
- Confirm that the robot’s repeatability and absolute accuracy meet the project requirements
- For an eye-to-hand setup, robot accuracy verification can be performed during the pre-calibration checks
- For an eye-in-hand setup, translate the robot end-effector and Calibration Board in the same direction and compare the two travel distances
- If accuracy does not meet the requirements, contact the robot manufacturer or address the robot accuracy issue according to the project requirements
For the specific check procedure, see the robot accuracy verification instructions in Common Issues and FAQ.
7. Check Results
| Check item | Pass criteria |
|---|---|
| Basic configuration | The project, task, camera, and robot communication are all configured |
| Robot installation | The base is secure, and the robot does not noticeably shake during movement |
| Camera installation | The camera and bracket are not loose and do not slip |
| Images and Point Cloud | The Calibration Board is detected consistently, and exposure and Point Cloud quality are normal |
| Calibration Board and tool | There is no damage or deformation, and the mounting arrangement matches the calibration method |
| Robot accuracy | Meets the project’s operating requirements |
After all checks pass, return to the Eye-hand Calibration Process and select the eye-in-hand or eye-to-hand procedure.